Part Number Hot Search : 
LD7580A P80C552 HAT2051T QPH9232 MJD41C SCL40 24SM200S X7304
Product Description
Full Text Search
 

To Download FTM-9723P-KGHG Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Jun.7, 2006
2x10 SFF G-PON OLT Transceiver FTM-9723P-KGH(G)
Members of FlexonTM Family
Standard
Compliant with ITU-T G.984.2 Amendment 1 Compliant with FCC 47 CFR Part 15, Class B Compliant with FDA 21 CFR 1040.10 and 1040.11, Class
Description Features
Single fiber bi-directional 2488.32Mbps data links with and FTM-9723P-KGH(G) is Optical Line Terminal (OLT) compliant with ITU-T Rec.G.984.2 Amendment 1. The transceiver is the high performance module for 2488.32Mbps downstream and 1244.16Mbps upstream data link in single fiber by using 1490nm continuous-mode transmitter and 1310nm burst-mode receiver. The transmitter section uses a multiple quantum well 1490nm DFB laser and is Class laser compliant product according to international safety standard IEC-60825. The receiver section uses an integrated 1310nm APD (Avalanche Photo Diode) and preamplifier mounted in an optical header and limiting post-amplifier IC. Unlike the conventional burst-mode receiver, the receiver does not require reset pulse to receive optical data packets with different optical power. The optical output can be disabled by a LVTTL logic high-level input of TX_DIS. LAS_FAIL is provided to indicate that degradation of the laser. Signal Detected (SD) output is provided to indicate the detection of an input optical signal of receiver. Digital diagnostic monitoring interface is incorporated into the transceivers and allows real time access to the transceiver operating parameters such as power supply, operating temperature, laser bias current, transmitter optical power by reading a built-in memory with I2C interface. Analog RSSI signal indicate the received Gigabit-capable Passive Optical Networks (G-PON) - OLT side optical power value and the calibration parameters are stored in the memory. Doc No: DS3633001-1d
asymmetric
downstream
1244.16Mbps upstream Integrated with micro-optics WDM filter for dual wavelength Tx/Rx operation at 1490/1310nm 1490nm continuous-mode transmitter with DFB laser 1310nm burst-mode receiver with APD-TIA Optical isolator built in for extreme Return Loss tolerance Resetless burst-mode receiver design Support Class B+ attenuation range 13-28dB Support more than 20dB dynamic range 0 to 70C operating temperature 2 x10 SF F package with SC/UPC pigtail Digital diagnostic monitoring interface Analog RSSI (Received Signal Strength Indication) for monitoring on received optical power. Single 3.3V power supply LVPECL compatible data input/output interface LVTTL transmitter disable control LVTTL transmitter fault alarm LVTTL receiver signal-detected indication Low EMI and excellent ESD protection Classlaser safety standard IEC-60825 compliant
Applications
Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 1 of 16
2x10 SFF G-PON OLT Transceiver (Temporary Version) Class B+ attenuation range: 13-28dB Jul.7,2006
Regulatory Compliance
The transceivers have been tested according to American and European product safety and electromagnetic compatibility regulations (See Table 1). For further information regarding regulatory certification, please refer to FlexonTM regulatory specification and safety guidelines, or contact with Fiberxon, Inc. America sales office listed at the end of documentation. Table 1 - Regulatory Compliance
Feature Electrostatic Discharge (ESD) to the Electrical Pins Electromagnetic Interference (EMI) Immunity Laser Eye Safety Component Recognition Pigtail Integrity MIL-STD-883E Method 3015.7 FCC Part 15 Class B EN55022 Class B (CISPR 22B) VCCI Class B IEC 61000-4-3 FDA 21CFR 1040.10 and 1040.11 EN60950, EN (IEC) 60825-1,2 UL and CSA GR326 and GR468 Compliant with standards Compliant with Class I laser product Compliant with standards Compliant with standards Compliant with standards Standard Performance Class (>500 V)
Absolute Maximum Ratings
Absolute Maximum Ratings are those values, beyond which, some damage may occur to the devices. Exposure to conditions above the Absolute Maximum Ratings listed in Table 2 may negatively impact the reliability of the products. Table 2- Absolute Maximum Ratings
Parameter Storage Ambient Temperature Operating Case Temperature Operating Humidity Power Supply Voltage Input Voltage Receiver Damaged Threshold Soldering Temperature Bending Radius Pigtail Fiber Contact Temperature 30 85 Symbol TSTG TC HOPR VCC Min. -40 0 5 0 GND 0 400 Max. 85 70 95 4 Vcc Unit C C % V V dBm C mm C 1 Note
Note 1: Only for soldering by iron and 10 seconds on leads only
Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 2 of 16
Doc No: DS3633001-1d
2x10 SFF G-PON OLT Transceiver (Temporary Version) Class B+ attenuation range: 13-28dB Jul.7,2006
Recommended Operating Conditions
Table 3 - Recommended Operating Conditions
Parameter Power Supply Voltage Operating Case Temperature Operating Humidity Range Data Rate(Upstream/Downstream) Symbol VCC TC HOPR Min. 3.13 0 5 1244.16/2488.32 Typ. 3.3 Max. 3.47 70 95 Unit V C % Mbit/s Note 3.3V5%
Optical and Electrical Characteristics
Table 4 - Transmitter Optical and Electrical Characteristics (0C Parameter Optical Center Wavelength Optical Spectrum Width (-20dB) Side Mode Suppression Ratio Average Launch Power (BOL) Average Launch Power (EOL) Average Launch Power-OFF Transmitter Extinction Ratio Symbol C SMSR POUT POFF ER 10 30 +2.0 +1.5 +5 +5 -39 Min. 1480 Typ. Max. 1500 1 Unit nm nm dB dBm dBm dBm dB 2 2,3 1 Note
Transmitter Eye Diagram
Optical Return Loss Tolerance Optical Path Penalty Data Input Differential Swing Input Differential Impedance Power Supply Current Transmitter Disable Voltage - Low Transmitter Disable Voltage - High Transmitter Failure Alarm Voltage - Low Transmitter Failure Alarm Voltage - High TDP VIN ZIN ICC_TX VTDIS, L VTDIS, H VLFA, L VLFA, H
Compliant With ITU-T G.984.2 15
0.5 200 90 0 2.0 0 2.4 100 1600 110 180 0.8 VCC 0.4 VCC
dB
dB mV mA V V V V 6 7 4 5
Note 1: Launched into 9/125um Single Mode Fiber. Note 2: Measured with PRBS 223-1 plus 72bits CID test pattern@2488.32Mbit/s, and the Bessel-Thompson filter is turned on. Note 3: Transmitter eye mask definition is shown as below.
Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 3 of 16
Doc No: DS3633001-1d
2x10 SFF G-PON OLT Transceiver (Temporary Version) Class B+ attenuation range: 13-28dB Jul.7,2006
2488.32Mbit/s x1/x4 x2/x3 x3-x2 y1/y2 ----0.2 0.25/0.75
Note 4: Maximum sensitivity penalty due to transmitter and dispersion effect through 20km of SMF optical fiber. Note 5: Compatible with LVPECL/CML input, AC coupled internally. (See Recommended Interface Circuit) Note 6: TX_DIS (See Pin Function Definitions) Note 7: LAS_FAIL (See Pin Function Definitions) Table 5 - Receiver Optical and Electrical Characteristics (0C Parameter Operating Wavelength Sensitivity Saturation Amplitude Recovery Time Dynamic Range Signal-Detected Assert Level Signal-Detected Deassert Level Signal-Detected Hysteresis Optical Return Loss Tolerance Power Supply Current Data Output Voltage - Low Data Output Voltage - High Signal-Detected Voltage - Low Signal-Detected Voltage - High ICC_RX VOL-VCC VOH-VCC VSD, L VSD, H -1.81 -1.02 0 2.4 PSDA PSDD PSDA- PSDD -45 0.5 6 PSEN PSAT TRECOVERY -28 -8 1 -8 -30 Symbol Min. 1260 Typical Max. 1360 -28 Unit nm dBm dBm Bit dBm dBm dBm dBm 1 1,2 1,3 4 5 Notes
10
250 -1.62 -0.88 0.4 VCC
dB
mA V V V V
6
7
Note 1: Measured with Fiberxon GPON ONT and a PRBS 223-1 Plus 72CID test pattern @1.25Gbit/s, BER =10-10. Note 2: See Figure 1,2. Measured with the Fiberxon GPON ONT and the TGUARD=25.6ns Note 3: See Figure 3.TRECOVERY be less than 1 bit is guaranteed. Measured with the Fiberxon GPON ONT and the TGUARD=25.6ns. Note 4: An increase in optical power above the specified level will cause Signal-Detected (SD) output to switch from a low state to a high state. Note 5: A decrease in optical power below the specified level will cause Signal-Detected (SD) output to switch from a high state to a low state. Note 6: LVPECL output, DC coupled internally, guaranteed in the full range of input optical power (-8dBm to -30dBm) (See Recommended Interface Circuit) Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 4 of 16 Doc No: DS3633001-1d
2x10 SFF G-PON OLT Transceiver (Temporary Version) Class B+ attenuation range: 13-28dB Jul.7,2006
Note 7: SD (See Pin Function Definitions) Optical Signal (1-Level)
Optical Signal Output (at ONT side)
TON TOFF
Optical Signal (0-Level) Dark Level
Upstream Data (TD+/TD- at ONT side)
Tx_BRST (at ONT side)
TRECOVERY
Upstream Data (RD+/RD- at OLT side) Data
Valid Packet
Figure 1 Timing Parameter Definition in Burst Mode Sequence (Sole ONT Application)
Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 5 of 16
Doc No: DS3633001-1d
2x10 SFF G-PON OLT Transceiver (Temporary Version) Class B+ attenuation range: 13-28dB Jul.7,2006
TX_BRST(Soft ONT) TEN_DUR TX_BRST(Loud ONT) TDIS_DUR
Optical Signal Output(Soft ONT) 1-Level OFF-Level 0-Level
TON1
TOFF1
Optical Signal Output(Loud ONT) 1-Level
TGUARD
TON2
TOFF2
0-Level OFF-Level TRECOVERY(SOFT) TRECOVERY(Loud)
Electrical Signal(OLT)
Figure 2 Timing Parameter Definitions in Burst Mode Sequence (Dual ONTs Application)
From Strong ONT(P O = -8dBm)
Optical Signal Input (At OLT Side)
20dB Optical Power Dynamic Range
From Weak ONT(P O= -28dBm)
Figure 3 Burst Mode Receiver Dynamic Range in G-PON System
Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 6 of 16
Doc No: DS3633001-1d
2x10 SFF G-PON OLT Transceiver (Temporary Version) Class B+ attenuation range: 13-28dB Jul.7,2006
Recommended Interface Circuit
Figure 4 shows the recommended interface schemes.
VEET(12,16) +3.3V 2x1uH 10uF 0.1uF 10uF +3.3V PON_TX_DISABLE 4.7-10K Tx_Fault(CPU IO) TXP Z=50 0.1uF 0.1uF VCCT(11) VCCR(7) VEER(3,6) TX_DIS(13) LAS_FAIL(19) TD+(14) 100
FTM-9723P-KGH(G)
+3.3V 10K
TXN 2x150
Z=50
TD-(15)
CM Laser Driver
G-PON MAC
SerDes
2x130 RXN RXP 2x82
+3.3V Z=50 Z=50 RD-(9)
RD+(10) +3.3V 10K SD(8) Pmon(2)
BM Limiting Amplifier
PON_LOS
VCC(+3.3V) 2x4.7-10K SCL (17) SDA (18)
Monitoring
Temperature Supply Voltage TX Bias Current TX Optical Power
EEPROM
Figure 4 Recommended Interface Circuit
Pin Definitions
2x10 SFF planform in Figure 5 below shows the pin information of electrical interface and mounting studs. Functions are described in Table 6 with some accompanying notes.
Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 7 of 16
Doc No: DS3633001-1d
2x10 SFF G-PON OLT Transceiver (Temporary Version) Class B+ attenuation range: 13-28dB Jul.7,2006
Figure 5 2x10 SFF Planform Table 6 - Pin Function Definitions
Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 F Name NC Pmon VEER NC NC VEER VCCR SD RDRD+ VCCT VEET TX_DIS TD+ TDVEET SCL SDA LAS_FAIL NC MS Description No Function Definition Analog Received Optical Power Monitoring Receiver Signal Ground No Function Definition No Function Definition Receiver Signal Ground Receiver Power Supply Receiver Signal-Detected Indication Inverted Receiver Data Output Non-inverted Receiver Data Output Transmitter Power Supply Transmitter Signal Ground Transmitter Disable Transmitter Non-inverted Data Input Transmitter Inverted Data Input Transmitter Signal Ground Clock Line of the I2C interface Data Line of the I2C interface Laser Failure Alarm Indication No Function Definition Mounting Studs 6 7 Not connected 8 4 5 2 3 Not connected Not connected Notes Not connected 1
Note 1: Analog RSSI signal indicate the received average optical power value, which is calculate by the following equation:
Rx_PWR (0.1 W) = Rx_PWR(4)*Rx_RSSI 4 (mV) + Rx_PWR(3)*Rx_RSSI3 (mV) + Rx_PWR(2)*Rx_RSSI 2 (mV) + Rx_PWR(1)*Rx_RSSI (mV)+ Rx_PWR(0)
Rx_RSSI is the test value of the output RSSI signal with the unit of the millivolt; Rx_PWR(0-4) is the calibration parameters for the Rx received optical power calculation, which is stored in the EEPROM. (See Monitoring Specification) Note 2: LVTTL logic output, with internal 10K pull-up resistor. Optical Signal-Detected: High; Optical Signal Loss: Low Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 8 of 16 Doc No: DS3633001-1d
2x10 SFF G-PON OLT Transceiver (Temporary Version) Class B+ attenuation range: 13-28dB Jul.7,2006
Note 3: LVPECL logic output, DC coupled internally (See Recommended Interface Circuit) Note 4: LVTTL logic input, with internal 10K pull-up resistor. Transmitter Disabled: High; Transmitter Enabled: Low Note 5: LVPECL logic input, AC coupled with internal termination (See Recommended Interface Circuit) Note 6: I2C interface, they should be pulled up with two 4.7K-10K resistors on the host board. Note 7: TTL logic output, pulled up by a 4.7-10K resistor on the host board. Laser Normal State: Low; Laser Failure State: High Note 8:The mounting studs are provided for transceiver mechanical attachment to circuit board. They may also provide an optional connection of the transceiver to the equipment chassis ground. The holes in the circuit board must be tied to chassis ground. It is not recommended that the mounting studs be connected to signal ground.
Mechanical Design Outline
The form factor is 2x10 SFF with pigtail fiber. The pigtail fiber has a length of 520 - 550mm and 30mm minimum bending radius. The fiber connector type is SC/UPC. The mechanical design diagram is shown in Figure 6. (Dimension in mm)
4.81 0.05 10.16 8.89 19.3
0 20-0.50 -0.05
5.40.3
9.9 0.1
0 3.1-0.1
0.5
2.90.3
1.778
2-1 9x1.778(=16.002)
520~550
49.0 0.1 13.5
Label
Figure 6 Mechanical Design Outline Table 7- Pigtail Fiber Characteristics
Parameter Mode Field Diameter Cladding Diameter Jacket Diameter Bending Radius of Pigtail Fiber Tension Force on Pigtail Fiber Pigtail Fiber Length Optical Return Loss (SC/UPC type) -1490nm 520 50 30 1 550 Min. Typical 9 125 0.9 Max. Unit m m mm mm Kg mm dB
Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 9 of 16
0.9
12.310.3
MAX40.5
Doc No: DS3633001-1d
2x10 SFF G-PON OLT Transceiver (Temporary Version) Class B+ attenuation range: 13-28dB Jul.7,2006
EEPROM Information
The SFP MSA defines a 256-byte memory map in EEPROM describing the transceiver's capabilities, standard interfaces, manufacture, and other information, which is accessible over a 2 wire serial interface at the 8-bit address 1010000X(A0h). The memory contents refer to Table 8. Table 8 - EEPROM Serial ID Memory Contents(A0h)
Addr. 0 1 2 3-10 11 12 13 14 15 16 17 18 19 20-35 36 37-39 Field Size (Bytes) 1 1 1 8 1 1 1 1 1 1 1 1 1 16 1 3 Name of Field Identifier Ext. Identifier Connector Transceiver Encoding BR, Nominal Reserved Length (9um)-km Length (9um) Length (50um) Length (62.5um) Length (Copper) Reserved Vendor name Reserved Vendor OUI 02 04 0B XX XX XX XX XX XX XX XX 03 19 00 14 C8 00 00 00 00 46 49 42 45 52 58 4F 4E 20 49 4E 43 2E 20 20 20 00 00 00 00 46 54 4D 2D 39 37 32 33 40-55 16 Vendor PN 50 2D 4B 47 48 20 20 20 46 54 4D 2D 39 37 32 33 50 2D 4B 47 48 47 20 20 56-59 60-61 62 63 64-65 66 67 68-83 84-91 4 2 1 1 2 1 1 16 8 Vendor Rev Wavelength Reserved CC_BASE Options BR, max BR, min Vendor SN Date code XX XX 20 20 05 D2 00 XX 00 1A 00 00 XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX 20 20 ASCII Year(2 bytes),Month(2 bytes),Day(2 bytes) Check sum of byte 0-62 LOS,TX_FAULT and TX_DISABLE "FTM-9723P-KGH" (ASCII) "FTM-9723P-KGHG" (ASCII) ASCII("31 30 20 20" means 1.0 Revision) 1490nm Laser Wavelength "FIBERXON INC." (ASCII) 20(km) 200(100m) Not Support MMF Not Support MMF Not Support Copper Hex Description Module soldered to motherboard MOD4 Optical pigtail (Transmitter Code, not defined for G-PON) NRZ 2488.32Gbps transmission
Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 10 of 16
Doc No: DS3633001-1d
2x10 SFF G-PON OLT Transceiver (Temporary Version) Class B+ attenuation range: 13-28dB Jul.7,2006
Compliant with SFF-8472 V9.5 92 1 Diagnostic Monitoring Type 58 Externally Calibrated Received power measurement type -Average Power Diagnostics (Optional Alarm/warning flags) 93 1 Enhanced Options SFF-8472 Compliance CC_EXT Vendor Specific A0 Soft TX_FAULT monitoring implemented
94 95 96-255
1 1 64
02 XX
Diagnostics Compliance(SFF-8472 V9.5) Check sum of byte 64-94
Monitoring Specification
The digital diagnostic monitoring interface defines 256-byte memory map in EEPROM, which makes use of the 8 bit address 1010001X(A2h). Please see Figure 7. Table 9~11 show the EEPROM definition from 0 to 119 byte, please refer to the SFF-8472 Rev 9.5 for the data format of these tables. The monitoring specification of this product is described in Table 12.
Figure 7 EEPROM Memory Map Specific Data Field Descriptions
Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 11 of 16
Doc No: DS3633001-1d
2x10 SFF G-PON OLT Transceiver (Temporary Version) Class B+ attenuation range: 13-28dB Jul.7,2006
Table 9 - EEPROM Serial ID Memory of the Alarm and Warning Thresholds Contents in A2h
Addr. 00-01 02-03 04-05 06-07 08-09 10-11 12-13 14-15 16-17 18-19 20-21 22-23 24-25 26-27 28-29 30-31 32-55 Field Size (Bytes) 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 24 Name of Field Temp High Alarm Temp Low Alarm Temp High Warning Temp Low Warning Voltage High Alarm Voltage Low Alarm Voltage High Warning Voltage Low Warning Bias High Alarm Bias Low Alarm Bias High Warning Bias Low Warning TX Power High Alarm Tx Power Low Alarm Tx Power High Warning TX Power Low Warning Reserved Hex 55 00 FB 00 50 00 00 00 94 70 6D 60 8D CC 74 04 75 30 05 DC 61 A8 07 D0 9B 82 27 10 7B 87 31 2D 00 00 Description 85 Centigrade -5 Centigrade 80 Centigrade 0 Centigrade 3.8 V 2.8 V 3.6 V 3.0 V 60 mA 3 mA 50 mA 4 mA +6 dBm 0 dBm +5 dBm +1 dBm 0
Table 10 - EEPROM Serial ID Memory of the Calibration Constants Contents in A2h
Addr. 56-59 60-63 64-67 68-71 72-75 76-77 78-79 80-81 82-83 84-85 86-87 88-89 90-91 92-94 95 Field Size (Bytes) 4 4 4 4 4 2 2 2 2 2 2 2 2 3 1 Name of Field Rx_PWR(4) Rx_PWR(3) Rx_PWR(2) Rx_PWR(1) Rx_PWR(0) Tx_I(Slope) Tx_I(Offset) Tx_PWR(Slope) Tx_PWR(Offset) T (Slope) T (Offset) V (Slope) V (Offset) Reserved Checksum Hex XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX 01 00 00 00 01 00 00 00 01 00 00 00 01 00 00 00 00 00 XX 1 0 1 0 1 0 1 0 0 Check sum of byte 0-94 Description
Single precision floating point calibration data (various values at each device for incompatibility with "internal calibration")
Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 12 of 16
Doc No: DS3633001-1d
2x10 SFF G-PON OLT Transceiver (Temporary Version) Class B+ attenuation range: 13-28dB Jul.7,2006
Table 11 - EEPROM Serial ID Memory of the A/D Values and Status Bits Contents in A2h
Addr. 96-97 98-99 100-101 102-103 104-109 110 110 110 110 110 111 112 112 112 112 112 112 112 112 113-115 116 116 116 116 116 116 116 116 117-119 Bit 7-0 7-0 7-0 7-0 7-0 7 6~3 2 1 0 7-0 7 6 5 4 3 2 1 0 7-0 7 6 5 4 3 2 1 0 0-7 Name of Field Temperature Vcc TX Bias TX Power Reserved TX Disable State Reserved Laser Failure State Reserved Data_Ready_Bar Reserved Temp High Alarm Temp Low Alarm Vcc High Alarm Vcc Low Alarm TX Bias High Alarm TX Bias Low Alarm TX Power High Alarm TX Power Low Alarm Reserved Temp High Warning Temp Low Warning Vcc High Warning Vcc Low Warning TX Bias High Warning TX Bias Low Warning TX Power High Warning TX Power Low Warning Reserved 00 00 00 0 XX 00 00 00 0 XX 00 0 XX Hex XX XX XX XX XX XX XX XX 00 00 00 00 00 00 0 Description
Note: The "XX" byte should be filled in according to practical case. For more information, please refer to the related document of SFF-8472 Rev 9.5. Table 12- Monitoring Specification
Parameter Temperature Voltage Bias Current TX Power RX Power Range -20 to 80C 3.0 to 3.6V 0 to 100mA 0 to 6dBm -29 to -7dBm Accuracy 3C 3% 10% 3dB 3dB Calibration External External External External External
Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 13 of 16
Doc No: DS3633001-1d
2x10 SFF G-PON OLT Transceiver (Temporary Version) Class B+ attenuation range: 13-28dB Jul.7,2006
Ordering Information
FTM
9
7
2
3
P
K
G
H
X
Wavelength
9: Multiwave in Single Fiber
Connetor Type
P: Pigtail SC /UPC
Function
7: Burst 1490nm Tx/1310nm Rx
Package
K: SFF 2 x10
RoHS
G: RoHS compliant
Bit Rate(U)/(D)
23: 1244.16M/2488.32M
Part No. FTM-9723P-KGH FTM-9723P-KGHG
Distance
GH: G-PON Class B +
Product Description 1490nm(TX)/1310nm(RX), SC/UPC Pigtailed 2x10 SFF for G-PON OLT Class B+ attenuation range (13-28dB), 0C ~70C. 1490nm(TX)/1310nm(RX), SC/UPC Pigtailed 2x10 SFF for G-PON OLT Class B+ attenuation range (13-28dB), 0C ~70C, RoHS compliance
Related Documents
For further information, please refer to the following documents: SFF-8472 Rev 9.5 ITU-T G984.2 ITU-T G984.2 Amendment 1
Obtaining Document
You can visit our website: http://www.fiberxon.com Or contact with Fiberxon, Inc. America Sales Office listed at the end of documentation to get the latest documents.
Revision History
Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 14 of 16 Doc No: DS3633001-1d
2x10 SFF G-PON OLT Transceiver (Temporary Version) Class B+ attenuation range: 13-28dB Jul.7,2006
Reversion
Initiate
Review
Approve
Subject Initial datasheet (temporary) (Doc No. DS3633001-1a) 1) Replace the Operating Ambient Temperature Spec. with the Operating Case Temperature Spec. in the Table 2~3. 2) 3) Update the Average Launch Power, Optical Path Penalty spec. in the Table 4. Update the Saturation, Sensitivity, and Dynamic Range Spec. in the Table 5; 4) Replace the Receiver Threshold Settling Time Spec. with the Amplitude Recovery Time Spec. in the Table 5. 5) 6) Update the Power Supply Current spec. in the Table 5. Update the Figure 1~3. (Doc No. DS3633001-1b) (temporary) 1) Modify "Transmitter Failure Alarm Voltage" in Table 4, and "Signal-Detected Voltage" in Table 5.
Release Date
Pre 1a
Frank Zeng
Peter Tang
Peter Tang
Nov.18, 2005
Pre 1b
Frank Zeng
Peter Tang
Peter Tang
Dec.1, 2005
Pre 1c
Frank Zeng
Peter Tang
Peter Tang
2) 3)
Modify Figure 1, 2. Append EEPROM Serial ID Memory Contents (A0) in Table 8.
Dec.15, 2005
(Doc No. DS3633001-1c) (temporary) Revise datasheet(temporary) Pre 1d Frank Zeng Peter Tang Peter Tang Append new P/N: FTM-9723P-KGHG (Doc No. DS3633001-1d) Jul.7, 2006
(c) Copyright Fiberxon Inc. 2006 Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 15 of 16 Doc No: DS3633001-1d
2x10 SFF G-PON OLT Transceiver (Temporary Version) Class B+ attenuation range: 13-28dB Jul.7,2006
All Rights Reserved. All information contained in this document is subject to change without notice. The products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. The information contained in this document does not affect or change Fiberxon's product specifications or warranties. Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Fiberxon or third parties. All information contained in this document was obtained in specific environments, and is presented as an illustration. The results obtained in other operating environment may vary. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN "AS IS" BASIS. In no event will Fiberxon be liable for damages arising directly from any use of the information contained in this document. Contact U.S.A. Headquarter: 5201 Great America Parkway, Suite 350 Santa Clara, CA 95054 U. S. A. Tel: 408-562-6288 Fax: 408-562-6289 Or visit our website: http://www.fiberxon.com/
Fiberxon Proprietary and Confidential, Do Not Copy or Distribute Page 16 of 16
Doc No: DS3633001-1d


▲Up To Search▲   

 
Price & Availability of FTM-9723P-KGHG

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X